Standard Operation
- Dirty air enters chambers.
- Air is pulled through filter media.
- Clean air exits.
Pulse Cleaning
- Pulsed air shoots directly into filter media.
- Dust particles are shot directly into the hopper.
|
|---|
Zero-Turn Pulse Cleaning System
We call it Zero-Turn because the pulsed air is blown directly into the filters for maximum cleaning effectiveness. The V configuration of the PowerCore filter packs aligns the flutes in a near vertical formation allowing the dust to be pulsed directly into the hopper, preventing pulsed dust from being re-entrained on adjacent filter packs. Other collectors don’t feature this directional alignment.
 |
 |
Other Collectors
Pulsed dust blows from filter to filter. |
Powercore Collectors
Pulsed dust is shot directly into the hopper. |
|---|